Propeller sensor MBA 9 Fl
Originally manufactured level sensor from MAIHAK, later MAIHAK-SICK for horizontal installation. The sensor has not been manufactured for many years, but there is a replacement in the new series. You can use the parameters below to correctly identify the replacement.
MBA 9 Fl / CSA for CSA snadard
| Technical data | |
|---|---|
Grain size: |
0...15 mm |
| Working position: |
perpendicular from above
|
|
Immersion depth:
|
max. 15 m |
| Shaft: | flexible steel rope shaft MBA 9 Fl 8 mm, shaped thimble up to 3 m or 8 mm and rolled thimble or 12 mm and rolled thimble |
| Blade size: | 98mm x 40mm cross or 98mm x 98mm for lightweight materials |
|
Submerged material:
|
shaft, sealing scale and stainless steel impeller
|
|
Evaluation part material:
|
Al cast |
| Protection DIN 40050: |
Evaluation part IP 54, submerged part IP 65
|
| Flange: | Flange DN 100 PN6 or G 1 _ |
| Power supply: | 230VAC, 115VAC, 24VAC, 42VAC, with tolerance 15%, 50/60 Hz, 12VDC, 24VDC, 60VDC, with tolerance 5% |
|
Power consumption:
|
3 VA |
|
Transport and storage temperature:
|
- 20°C...+60°C |
|
Material temperature:
|
max.+80°C - (does not apply to special designs) |
|
Ambient temperature:
|
max.+60°C - (does not apply to special designs) |
| Overpressure in the tank: | max. 0,8 bar (0,08 MPa) - (does not apply to special designs) |
|
Products since 2000:
|
-0,5 bar ...+3 bar (does not apply to version Z10) |
| Weight: | ca. 2 kg + 1 kg/m shaft |
|
Special design
| |
| Hypertension: | MBA 9 Fl D10 - 10bar (1,0 MPa) |
| High temperature: | MBA 9 Fl T200 /D10 - 200°C, 10bar (1,0 MPa) MBA 9 Fl T500 /D10 - 500°, 10bar (1,0 MPa) |
|
Special sealing:
|
MBA 9 Fl DT - protection against abrasive material and steam MBA 9 Fl DTR - protection against abrasive gases, eg in the presence of sulfur |
| Special CSA design: | |
| Special design Ex | |
| Ex zone 10: | MBA 9 Fl / Z10 this type can be used for flammable environmentsdust explosion hazard zone 10 |
|
Danger of dust explosion:
|
allowed BVS St Ex 5/82
|
| Volby: | |
| Indicator light on the evaluation part: | A1 |
| Anodized evaluation part: | B1 |
| Permacron protective varnish: | B2 |
| Unpainted: | B3 |
| Tropical protection: | B4 |
|
Time delay:
|
E1 |
| Run control: | E2 |
| Freewheel: | F |
| Electric heating: | H |
|
Coating (Viton):
|
K1 |
|
Teflon-coated propeller and axle:
|
K2 |
| Protective tube, stainless steel (1 ", 500mm): | S |
| Continuous setting of limits: | V |
| Faster engine: | U |
| Orders: | |
| Design: (standard or special design) |
|
| Embodiment-N- or -R-: | |
| Flange or thread: | |
| Impeller length: | |
| Impeller size: | |
| Power supply: | |
| Options: | |